Analog Output Rotary Sensors

At the output of sensor a variable voltage or variable current is provided proportionally to the position of shaft / axis over a complete angle range of 360° or a subrange. The contactless sensor electronic guarantees a steady signal level and a low independent linearity error of ±0.5%.

In the default version, direction of rotation is clockwise and mechanical angle is 360° continuous without stop. Counter clockwise direction can also be programmed if required. Any angle from 0-20° to 0-360° can be programmed in steps of 1°. Analog interface has resolution of 4096 steps i.e.12 bit. Following outputs are available : Analog Outputs : 0-5V ratiometric, 0-5V DC, 0-10V DC, 4-20mA, 0-20mA, 2 channel 0-5V ratiometric, 2 Channel 0-5V DC, 2 Channel 0-10V DC .

Ecoline Plastic Economical Housings with diameter of 22 or 28 mm ø is available in 3 mounting methods :